Test Case

Show / Hide direct link   <MAIN> 3630PA: AMT Inventory and Event log confirmation Test - PP-80502



Version 1.3
Created on 02/03/2007 16:04:23  by Imthias Subaier
Summary
Preconditions
Status:   New
Priority:   Medium
BASIC INFORMATION
Section:S/W Test Require attachment:No
Team:Network Group:Basic Function
Lessons Learned:No Phase:SIV (BBFV), SIT
Locations:Inhouse: AWS and Cambridge, Inhouse: AWS, Inhouse: Cambridge, Compal, Flextronics, Quanta, Wistron Owned By:Eiji Ogata/LENOVO
Objective:Confirm the releaibility of AMT device
CRITERIA
The inventory summary is a display of a subset of the inventory information queried from the Intel AMT device, such as the device manufacturer, BIOS version and date, and the Intel AMT version.
EUT QUANTITY
One system
EQUIPMENT
Network
Critical Attribute:[0] : ETN - Ethernet

CONFIGURATION
REFERENCE PROCEDURE
Please refer detail section
STATISTIC INFO
Operating System Win81-64bit Win81-32bit Win10-32bit Win10-64bit Win7- 64bit Win7- 32bit Total
Test Points
Duration
Workload
# Step actions Win81-64bitWin81-32bitWin10-32bitWin10-64bitWin7- 64bitWin7- 32bit
1 Open the inventory summary AAAAAA
2 Updating the Intel AMT inventory AAAAAA
3 View the Intel AMT log page AAAAAA
DETAILS
ATTENTION!! Please follow below information.
1. Please check Error and Warning message in Event Viewer before you start the test case and after you complete the test case, and report it to your team lead, then arrange to open defect, if needed.

2. Perform All Test in Battery Mode (Some of the test items need to perform in AC Mode, follow each Test Case).

3. All Test Activity should be performed with AMT Enabled as Default (applicable on vPro enabled systems).

4. Please check Usability / Cosmetic issues (correct sentence/appropriate display/etc.) and open defect, if needed.

For all the products supporting ME version 4.xx, Ctrl +P option will be shown during the temp.boot menu which can be launched by pressing F12 key during boot

For all the products supporting ME version 6.xx, Press ThinkVantage Button during POST to get the Ctrl + P option.


Open the inventory summary

1. Open the LSM console (Start | All Programs | LANDesk | LANDesk System Manager). Double-click the AMT device in the My devices list, then click System information | AMT | Intel AMT options.


NOTE:
1. When you open the Inventory summary window, the data is queried real-time from the device, not read from the database, so the dialog may take a moment to display.
2. A good method to determine whether a device is configured in TLS or non-TLS mode is to open the inventory summary and verify the protocol type ? HTTP for non-TLS mode and HTTPS for TLS mode.
3. If you there is no entry in Inventory summary like this, you can update invenroty by next steps.



Updating the Intel AMT inventory
In LSM and LDSM you can manually update the Intel AMT inventory data that is stored in the database.

2. In LSM console, double-click the AMT device in the My devices list, then click System information | AMT | Intel AMT options | Update inventory. (In the LDMS Win32 console you can select multiple devices and update all of their inventories at the same time.)

NOTE: If you install the LANDesk agent on a device and the IP address of the device changes (for example, because DHCP gave it a new address or the device was moved to a different subnet), the Inventory scanner will automatically update the IP address in the database on the next inventory scan. However, if you do not have the agent installed, the only way to update the IP address in the database is to run this Update Inventory operation.


To Confirm the AMT Logs are generated

View the Intel AMT log page

1. Open the LSM console (Start | All Programs | LANDesk | LANDesk System Manager). Double-click the AMT device in the My devices list, then click System information | Logs | Intel AMT log.
NOTE: The log can be cleared, refreshed, and exported to a CSV file.



3. Check for the other options available in the intel vPro system information: [UR-1901]

Test Item Check Item / Criteria
Result
Win XP
Win 7
Win 8
Health Summary

1. Open the LSM console(Start/All Programs/LANDesk/LANDesk System Manager).
2. Double-click on AMT device in My Devices list then click on System Information.
3. Click on to "Health Summary" and verify if the following items are present:
  • CPU
  • Network
  • Memory
  • Storage
  • Cooling
  • Power
  • Chasis
  • All information should be displayed in each devices shown in the health summary.
  • Correct and complete information should be displayed.
A
A
A
System Summary
1. Perform procedure no.1 and 2 in Health Summary section.
2. This time click on to "Sytem Summary" and make sure that the informations/specifications are displayed properly.
  • All information should be displayed in the system summary.
  • Correct and complete information should be displayed.



A



A



A
Hardware
1. In System Information list click on to "Hardware" and confirm if below items and their sub-items are available:

CPU
  • Processor
  • Cache

Storage
  • Logical Drives
  • Physical Drives
  • Removable Media
  • Storage Adapters

Memory
  • Memory Modules

Input Devices
  • Keyboard
  • Mouse

Motherboard
  • Motherboard
  • Expansion Slots
  • BIOS
  • All information should be displayed in each devices .
  • Correct and complete information should be displayed.










A










A










A
Logs
1. In System Information, click on to "Logs". Check the availability of the following:
  • Alert Log
  • Intel vPro log
  • Provisioning History
  • Log file should display correct time stamp, and information.


A


A


A
Software
1. Follow procedures 1 and 2 in the Health Summary item. Click on to "Software" and make sure the presence of the following criteria:
  • Packages
  • Environment
  • Correct list of softwares installed in system should be displayed.
  • Correct Registry entry should be displayed in the environment menu.



A



A



A
Intel vPro
1. At AMT Devices click on to System Information and then to "Intel vPro". Verify if the following items are available:
  • Intel vPro options
  • System defense status
  • Status of the system defense should be displayed in real-time operation.
  • All buttons under Intel vPro configuration options should be working properly



A



A



A
Others
1. By clicking "Others" in the System Information, below items should be available.

Asset information
  • Contact information
  • System information

Network information
  • Devices
  • Statistics
  • Configuration
  • Connections
  • All information should be displayed in each criteria.
  • Correct and complete information should be displayed.







A







A







A

System Status and Hardware Information Verification in WebUI - UR-2764

Test Item
Check Item/Criteria
Win XP
Win7
Win 8
  1. Log on to the WebUI.
  2. Under System status
  3. Make sure that System Id and UUID in Bios is identical
  4. Also check that the IP address ,date,time are displayed correctly
  • Log on to the WebUI should be successful and all the information should be displayed correctly
A
A
A
  • Log on to the WebUI.
  • Click on the Hardware Information and make sure following options are present
    • System
    • Processor
    • Memory
    • Disk
    • Battery
    3. Make sure that information displayed is correct and in accordance with the system.
    • Log on to the WebUI should be successful and all the information should be displayed correctly
    A
    A
    A
    OTHER DETAILS
    EUT Quantity : One system 1. "Please check Error and Warning message in Event Viewer before you start the test case and after you complete the test case, and report it to your team lead."
    2. "Perform All Test in Battery Mode (Some of the test items need to perform in AC Mode, follow each Test Case)"
    (All Test Activity should be performed with AMT Enabled)
    Test Item XP V32 V64

    TEMS Reviewer Log:03/05/2007 10:28:21 AM by Kazuo 1 Matsumoto/Japan/Lenovo/IDE (Review Comment: OK
    Review Logs
    Keywords:   None
    Requirements :   None
    Attached files :

    Update History:
    This document is not yet modified.