Test Case

Show / Hide direct link   <MAIN> 3636PA: Out of Band monitor Test - PP-80448



Version 1.2
Created on 02/03/2007 17:26:13  by Imthias Subaier
Summary
Preconditions
Status:   New
Priority:   Medium
BASIC INFORMATION
Section:S/W Test Require attachment:No
Team:Network Group:Advanced Function
Lessons Learned:No Phase:SIV (BBFV), SIT, SVT
Locations:Inhouse: AWS and Cambridge, Inhouse: AWS, Inhouse: Cambridge, Compal, Flextronics, Quanta, Wistron Owned By:Eiji Ogata/LENOVO
Objective:To confirm the reliability of AMt device
CRITERIA
Check this function works fine without any issues
EUT QUANTITY
1 system
EQUIPMENT
PPA Network facilties
Critical Attribute:[0] : ETN - Ethernet

CONFIGURATION
REFERENCE PROCEDURE
Refer detail section
STATISTIC INFO
Operating System Win81-64bit Win81-32bit Win10-32bit Win10-64bit Win7- 32bit Total
Test Points
Duration
Workload
# Step actions Win81-64bitWin81-32bitWin10-32bitWin10-64bitWin7- 32bit
1 Test the monitoring features AAAAA
2 How to check Out of Band in 32-bit Console AAAAA
3 How to check Out of Band in Web Console AAAAA
DETAILS
ATTENTION!! Please follow below information.
1. Please check Error and Warning message in Event Viewer before you start the test case and after you complete the test case, and report it to your team lead, then arrange to open defect, if needed.

2. Perform All Test in Battery Mode (Some of the test items need to perform in AC Mode, follow each Test Case).

3. All Test Activity should be performed with AMT Enabled as Default (applicable on vPro enabled systems).

4. Please check Usability / Cosmetic issues (correct sentence/appropriate display/etc.) and open defect, if needed.

Starting with version 8.6.0, LANDesk products have the ability to disable the network at the OS level on Intel AMT devices. This was not done through the Intel AMT System Defense feature, but rather it was done through LANDesk agents and communicating via the Intel AMT non-volatile memory (NVM) area. When the user chooses to disable the network, a value is written to a location in the NVM that a service called LANDesk Out-of-band Monitor (AMTMON.EXE) on the client is monitoring. If the service sees the flag to disable the network, it does so. If it sees the flag to enable the network, it does that. And if it sees the flag to run the vulnerability scan on the next reboot, it sets that up. A message box pops up on the managed device notifying the user when any of the three operations is performed.


[Procedure] :


Test the monitoring features

1. Double-click the device in the My devices list, then click System information | AMT | Intel AMT options.

2. Under Configuration options, click Enable, Disable, or Scan.
Note: Do not ping the Intel AMT device to test if the network is disabled, as Intel AMT may still respond to pings.



Confirm following options are available in both Enterprise mode/SMB mode and the functions are working UR-01741DS

1. Install AMT 2.5 Management engine interface, Local manageability service & SOL driver and restart.
2. Enable AMT . Install the agent in the AMT 2.5 device.
3. Open the LANDesk Management Suite console, select Network View | LDMS-SERVERNAME | Devices | All devices and check the AMT2.5 device is listed.
4. Now right click AMT 2.5 device and goto Intel AMT options and check configuration options are available.
Note: Configuration options such as "Disable OS network", "Enable OS network" and "Run security scan on reboot"


Confirmation using LANDesk 8.8 : [UR-1915DS]

How To check Out of Band in 32-bit Console
Step 1:Set Out Of Band

  1. Open the LDSM console (Start | All Programs | LANDesk | LANDesk Management Suite).
  2. Right click on the target device on the device list. Select Intel vPro Options | Disable OS Network.

Step 2:Test Out Of Band Monitor
  1. On that AMTdevice, a dialog will open. You can know that the OOB is configured.
  2. On the LDMS server, ping to the target device. Comfirm that returned ping's TTL is 255.

Step 3:Resume network
  1. On the LDMS server, Right click on the target device on the device list. Select Intel vPro Options | Enable OS Network.
  2. On that AMTdevice, a dialog will open. You can know that the OOB is configured.
  3. On the LDMS server, ping to the target device. Comfirm that returned ping's TTL is 128.


How To check Out of Band in Web Console
Step 1:Set Out Of Band
  1. Open the LSM console (Start | All Programs | LANDesk | LANDesk System Manager) and double click the target device.
  2. Click Intel vPro | Intel vPro Options | Disable.

Step 2:Test Out Of Band Monitor
  1. On that AMTdevice, a dialog will open. You can know that the OOB is configured.
  2. On the LDMS server, ping to the target device. Comfirm that returned ping's TTL is 255.

Step 3:Resume network
  1. On the LDMS server, Click Intel vPro | Intel vPro Options | Enable.
  2. On the LDMS server, ping to the target device. Comfirm that returned ping's TTL is 128.


OTHER DETAILS
EUT Quantity : 1 system 1. "Please check Error and Warning message in Event Viewer before you start the test case and after you complete the test case, and report it to your team lead."
2. "Perform All Test in Battery Mode (Some of the test items need to perform in AC Mode, follow each Test Case)"
(All Test Activity should be performed with AMT Enabled)
Test Item XP V32 V64

TEMS Reviewer Log:03/05/2007 10:34:03 AM by Kazuo 1 Matsumoto/Japan/Lenovo/IDE (Review Comment: OK
Review Logs
Keywords:   None
Requirements :   None
Attached files :

Update History:
This document is not yet modified.